Products Respirometer Systems Gas Endeavour® III

Gas Endeavour® III

Gas Endeavour® III

Gas Endeavour® III helps laboratories monitor low gas production or gas consumption across applications such as animal nutrition, wastewater analysis, biohydrogen, fermentation studies, biogas research and microbial activity testing.

  • Low gas volume and flow
  • 18 or 9 reactor channels
  • Aurora™ software included
Close up of the AMPTS III system showing the gas measurement unit, CO₂ absorption bottles and sample reactors used for automated anaerobic batch fermentation testing.

Follow gas production with less manual work

Gas Endeavour® III is a laboratory instrument platform for precise evaluation of gas production or gas consumption in batch and continuous processes. It helps laboratories follow gas volume and flow over time, compare samples and reduce manual readings during long running experiments.

The system is available with 18 or 9 parallel channels and can be configured for different laboratory workflows, including standard gas measurement, animal nutrition, DUO and MAX packages. It is designed for both research and industrial laboratories that need reliable gas data from biological processes.

Mentioned in

63

scientific publications

Choose between

9 or 18 channels

Run samples, blanks, controls and replicates in parallel

Software

Aurora™ included

Set up, monitor and export data in the browser

Automated gas measurement

Record gas volume and flow automatically during batch or continuous tests.

Parallel reactor setup

Analyse samples, blanks, controls and replicates in parallel with 9 or 18 reactor channels.

Browser based software

Included Aurora™ software lets users set up, monitor and review experiments remotely and locally in the browser.

Automated compensation

Real time pressure, temperature and moisture compensation helps normalise gas volume and flow data to standard conditions.

Easy data export

Export experiment data as spreadsheet files with a uniform time axis for further analysis and reporting.

Controlled incubation and mixing

Maintain stable test conditions with thermostatic incubation and adjustable mechanical agitation.

Flexible measurement resolution

Choose between 2 ml and 9 ml flow cell resolutions depending on the test setup.

Modular maintenance

The modular design makes it easier to exchange many parts without sending the full system for service.

Why choose Gas Endeavour® III?

Built for flexible gas measurement

Gas Endeavour® III is designed for laboratories that need precise gas volume and flow data across different biological process applications.


One platform for several workflows

Use the system for in vitro digestibility, wastewater analysis, biohydrogen studies, ethanol fermentation, biogas research, microbial activity testing and biodegradability related workflows.


Less manual work

After experiment preparation and setup, gas measurement and data recording are automated throughout the test period.


Structured data handling

Gas measurements, experiment settings and exported results are handled in one platform, reducing the need for separate files and manual calculations.


Configurations for different needs

Choose between Standard, Animal Nutrition, DUO, MAX and Light configurations depending on your application, sample throughput and reactor setup.


Get a quote
within 48 hours

Request a quote from our sales team for Gas Endeavour® III or other respirometry systems. Share your application, expected sample throughput and the type of gas measurement you need. Our product experts can help you choose the right Gas Endeavour® III configuration and suitable accessories for your laboratory.

Get a quote for
Gas Endeavour® III

"*" indicates required fields

Trusted by teams globally

Aurora™ Software inlcuded

Aurora™ is the experiment software included with Gas Endeavour® III . It is accessed through a web browser and gives users a clear way to set up tests, follow gas production, store data and export results without installing software on an external computer.

With local data storage and remote access, laboratories can follow long running anaerobic batch or continuous tests from the lab, office or another location.

  • Experiment setup in the browser
  • Real time gas production monitoring
  • Local data storage on the instrument
  • Spreadsheet export for further analysis
  • Remote access from computer, tablet or smartphone

Suitable application workflows

Animal and human nutrition

Monitor fermentation gas production in ruminant, monogastric and human gut models. Gas Endeavour® III is used for in vitro digestibility studies, feed evaluation, feed additive screening and fermentation kinetics.

Biogas research

Use gas volume and flow data to study biological conversion, microbial activity and gas production behaviour in anaerobic processes.

Wastewater analysis

Follow gas production, gas consumption or oxygen uptake in wastewater, sludge and biological treatment studies.

Biohydrogen

Measure gas production in biohydrogen potential and dark fermentation studies.

Fermentation studies

Monitor gas production or consumption during ethanol fermentation and other microbial process studies.

Microbial activity

Evaluate the behaviour of microbial communities through gas production or gas consumption under controlled laboratory conditions.

Choose the configuration that suits your workflow

Gas Endeavour III Standard
Application areas In-vitro digestability, bioethanol production, yeast fermentation and many more general applications
Measured gas volume Anaerobic gases (eg. biogas, biomethane, biohydrogen production)
Number of measurement channels 18
Reactor volume 0.5 L or 1.0 L
Gas composition estimation No
Operation modes Batch or continuous
Carbon dioxide removal Ex-situ
Measurement resolution 2 mL and 9 mL
Software Aurora software
Gas Endeavour III MAX
Application areas In-vitro digestability, biodegradability, bioethanol production, yeast fermentation and many more general applications
Measured gas volume Anaerobic gases (eg. biogas, biomethane, biohydrogen production), oxygen consumption
Number of measurement channels 18 (9 in continuous mode)
Reactor volume 1.0 L and 2.0 L
Gas composition estimation With DUO Configuration
Operation modes Batch and continuous
Carbon dioxide removal Ex situ or in situ
Measurement resolution 2 mL and 9 mL
Software Aurora software
Gas Endeavour III Animal Nutrition
Application areas Feed digestibility, rumen fermentation
Measured gas volume Anaerobic gases (eg. biogas, biomethane, biohydrogen production)
Number of measurement channels 18
Reactor volume 250 mL
Gas composition estimation No
Operation modes Batch and continuous
Carbon dioxide removal Ex-situ
Measurement resolution 2 mL
Software Aurora software
Gas Endeavour III Light
Application areas In-vitro digestability, bioethanol production, yeast fermentation and many more general applications
Measured gas volume Anaerobic gases (eg. biogas, biomethane, biohydrogen production)
Number of measurement channels 9
Reactor volume 2.0 L
Gas composition estimation No
Operation modes Batch and continuous
Carbon dioxide removal Ex-situ
Measurement resolution 2 mL and 9 mL
Software Aurora software

Choose your incubation setup

Gas Endeavour® III can be used with a thermostatic water bath, a shaking thermostatic water bath for animal nutrition workflows, or BPC® Air depending on the configuration and application.

BPC® Air

BPC® Air can be used as an air based incubation unit for Gas Endeavour® III instead of a traditional thermostatic water bath. It provides heating and cooling from 10 to 60 °C and removes the need to refill incubation medium during long tests.


Shaking thermostatic water bath

The Animal Nutrition configuration uses a shaking thermostatic water bath with 250 mL reactors, supporting controlled incubation and mixing in smaller reactors for in vitro fermentation studies.


Thermostatic water bath

The standard incubation setup provides water based temperature control for Gas Endeavour® III workflows. It is suitable for laboratories that already use water bath incubation or need controlled conditions for biological process tests.


Downloads

Download product brochures and comparison documents.

Looking for manuals or other technical documentation?
You can find them in BPC Academy, our customer resource and training centre.

Want to know more?

Need help choosing between Gas Endeavour® III models?

Tell us about your sample throughput, reactor volume and test type. We can help you identify the right configuration.

Technical Specifications

Incubation unit (Standard)

The standard incubation unit is used for Gas Endeavour® III workflows that require controlled temperature conditions and consistent mixing. It supports 9 or 18 glass reactors and is suitable for batch and continuous biological process studies where gas production or gas consumption is measured over time.

It uses a thermostatic water bath with mechanical agitation to keep samples mixed during the experiment. Different reactor volumes are available depending on the application and test setup.

Maximum number of reactors per system 

18 or 9


Reactor material

Glass


Standard reactor volume

1000 mL (with option for 500 mL) and 2000 mL


Type

Thermostatic water bath


Dimensions

56 x 68 x 32 cm


Temperature control 

Up to 60 °C (203 °F) with a precision of 0.2 °C


Mixing in the reactor

mechanical agitation with brushless DC motors (adjustable interval, speed and rotation directions), max. speed 200 rpm


Power supply

Incubation unit (Animal Nutrition)

The Animal Nutrition incubation unit is designed for in vitro digestion and fermentation studies. It uses 250 ml glass reactors in a shaking thermostatic water bath, helping maintain controlled temperature and consistent sample movement during the experiment.

It supports 9 or 18 reactors and is suited for workflows where mixing and stable incubation are important, such as ruminant, monogastric and human gut fermentation models.

Maximum number of reactors per system 

18 or 9


Reactor material

Glass


Standard reactor volume

250 mL


Type

Shaking thermostatic water bath


Dimensions

53 x 33 x 28 cm


Temperature control 

up to 99 °C (210 °F)


Power supply

Incubation unit (BPC® Air)

BPC® Air is a dedicated incubation unit for BPC respirometer systems, including BPC® Blue. It uses air as the heating and cooling medium, with a temperature range of 10 to 60 °C, which makes it suitable for both aerobic and anaerobic BPC® Blue workflows.

Unlike a traditional water bath, BPC® Air requires no water refills during operation. It also has a floor standing design with wheels, so it can be moved and positioned more freely in the laboratory.

Maximum number of reactors per system 

18 or 9


Reactor material

Glass


Standard reactor volume

1000 mL (with option for 500 mL) and 2000 mL


Type

Air to air incubation


Dimensions

117 x 77 x 90 cm (182 with tubing rack)


Weight

51.6 kg


Temperature control 

10-60 oC


Mixing in the reactor

mechanical agitation with brushless DC motors (adjustable interval, speed and rotation directions), max. speed 200 rpm


Power supply

100-240 V & 50-60 Hz


Noise level

87.1 dBA / 86.2. dBC


Housing

Stainless steel, compact laminate and plastic


Operating humidity:

10-90 % RH non-condensing

Carbon dioxide absorption unit

The carbon dioxide absorption unit removes CO₂ from the gas stream before measurement, allowing Gas Endeavour® III to measure methane production directly during BMP testing. Each trap bottle is prepared with absorption liquid* and connects between the reactor and detection unit.

*Absorption liquid is not included with the instrument

Carbon dioxide trap bottles

18 or 9


Volume of carbon dioxide trap bottles

250  mL


Dimensions

54 x 27 x 12 cm (including bottles)


Recommended absorption liquid*

3 M NaOH with pH indicator*, 200 mL per bottle (not included) Absorption efficiency: >98%

Detection unit

The detection unit records gas production from up to 18 channels using liquid displacement and buoyancy. Built-in sensors and onboard electronics support stable, automated measurement, with data transferred to Aurora™ for monitoring, analysis and export.

Working principle

Liquid displacement and buoyancy 


Number of flow cell units

18 or 9


Dimension of unit

55 x 19 x 17 cm


Housing

Aluminium and plastic


Built-in sensors

Temperature, Pressure, Hall, Accelerometer 


Connections 

Up to 60 °C (203 °F) with a precision of 0.2 °C


Display

OLED 2.8” 256 x 64 white 


Power supply

12 V DC / 1.0 A with 100-240 VAC 


Measurement medium

Deionised or distilled water


Operation temperature

0 – 50o C


Operation pressure

-50 – 50 mbar


Gas connector diameter

ID: 2.4 – 2.6 mm; OD: 4.2-4.7 mm 


Recommended tubing size

ID: 4 mm;  OD: 6 mm 


Measuring resolution

9 mL and 2 mL 


Detection capacity

10 million data points


Measuring range

1 to 6000 mL/h for 9 ml flow cell  and 0.2 to 1500 mL/h


Repeatability

CV ≤ 1% for 9 ml flow cell and CV ≤ 3% for 2 ml flow cell 


Gases

Non aggressive gases (e.g. CH4 , CO2 , H2 , N2 ,…)

Related spare parts

Common questions about
Gas Endeavour® III

Gas Endeavour® III is used for precise gas volume and flow measurement in batch and continuous biological processes. Typical applications include animal nutrition, wastewater analysis, biohydrogen, fermentation studies, biogas research and microbial activity testing.


Gas Endeavour® III has 18 channels, while Gas Endeavour® III Light has 9 channels. The Light version is suited for laboratories with lower sample throughput.


Gas Endeavour® III is used for non-aggressive gases such as methane, carbon dioxide, hydrogen and nitrogen, depending on the experiment setup.


Yes. The Animal Nutrition configuration is designed for in vitro digestion and fermentation studies and uses 250 ml reactors with a shaking thermostatic water bath.


Yes. Gas Endeavour® III can be used in both batch and continuous operation modes.

No. Gas Endeavour® III has embedded software and local data storage. Aurora™ is accessed through a web browser, so no software installation on an external computer is required.

Yes. Gas Endeavour® III can be paired with BPC® Air as an air based incubation option instead of a traditional thermostatic water bath.


Scientific References

Talk to an expert about Gas Endeavour® III

Share your application, expected sample throughput and the type of gas measurement you need. Our product specialists can help you choose the right Gas Endeavour® III configuration and suitable accessories for your laboratory.

"*" indicates required fields