AMPTS® III

AMPTS® III

Automated anaerobic batch fermentation testing for BMP, SMA, residual gas potential and inhibition studies. AMPTS® III measures gas volume and flow from parallel anaerobic batch tests with automated data recording, normalisation and reporting. It is designed for laboratories that need reliable methane potential data with less manual handling.

  • BMP, SMA and RGP testing
  • 18 or 9 reactor channels
  • Aurora™ software included

A more reliable way to run BMP tests

AMPTS® III is a fully integrated system for anaerobic batch fermentation testing. It helps laboratories determine biochemical methane potential, follow degradation profiles and compare substrates, pre-treatments, inoculum activity or inhibition effects under controlled conditions.

The system supports BMP testing workflows based on VDI 4630 and combines glass reactors, mechanical agitation, CO₂ absorption, gas volume measurement and browser based software in one platform. Sampling, analysis, recording and report generation are handled in the same workflow, reducing manual readings and fragmented data handling.

Mentioned in

435

scientific publications

Choose between

9 or 18 channels

Run samples, blanks, controls and replicates in parallel

Software

Aurora™ included

Set up, monitor and export data in the browser

Automated batch testing

Run BMP, SMA, residual gas potential and inhibition studies with automated gas measurement and data recording.

Parallel reactor setup

Analyse samples, blanks, controls and replicates in parallel with 9 or 18 reactor channels.

Browser based software

Included Aurora™ software lets users set up, monitor and review experiments remotely and locally in the browser.

Automated compensation

Real time pressure, temperature and moisture compensation helps normalise gas volume and flow data to standard conditions.

Easy data export

Export experiment data as spreadsheet files with a uniform time axis for further analysis and reporting.

Controlled incubation and mixing

Maintain stable test conditions with thermostatic incubation and adjustable mechanical agitation.

Integrated biomethane workflow

Use CO₂ absorption units to measure accumulated biomethane, or remove the absorption unit to measure total biogas.

Modular maintenance

The modular design makes it easier to exchange many parts without sending the full system for service.

Why choose AMPTS® III?

Built for anaerobic batch testing

AMPTS® III is designed for biochemical methane potential testing and related anaerobic batch fermentation workflows.


One platform for several test types

Use the same system for BMP tests, SMA assays, residual gas potential analysis, inhibition studies, biogas potential and anaerobic biodegradability testing.


Less manual work

After experiment preparation and setup, gas measurement and data recording are automated throughout the test period.


Structured data handling

Gas measurements, experiment settings and exported results are handled in one platform, reducing the need for separate files and manual calculations.


Scalable lab capacity

Choose AMPTS® III with 18 channels or AMPTS® III Light with 9 channels, depending on sample throughput.


Get a quote
within 48 hours

Request a quote from our sales team for AMPTS® III or other respirometry systems. Share your application, expected sample throughput and the type of gas measurement you need. Our product specialists can help you choose the right AMPTS® III configuration and suitable accessories for your laboratory.

Get a quote for
AMPTS® III

"*" indicates required fields

Trusted by teams globally

Aurora™ Software inlcuded

Aurora™ is the experiment software included with AMPTS® III. It is accessed through a web browser and gives users a clear way to set up tests, follow gas production, store data and export results without installing software on an external computer.

With local data storage and remote access, laboratories can follow long running anaerobic batch tests from the lab, office or another location.

  • Experiment setup in the browser
  • Real time gas production monitoring
  • Local data storage on the instrument
  • Spreadsheet export for further analysis
  • Remote access from computer, tablet or smartphone

Choose the configuration that suits your workflow

AMPTS III Standard
Application areas Biogas, biomethane, BMP, SMA, RGP, biohydrogen
Measured gas volume Anaerobic gases (eg. biogas, biomethane, biohydrogen production)
Number of measurement channels 18
Reactor volume 0.5 L or 1.0 L
Gas composition estimation No
Operation modes Batch
Carbon dioxide removal Ex-situ
Measurement resolution 2 mL or 9 mL
Software Aurora software
AMPTS III Light
Application areas Biogas, biomethane, BMP, SMA, RGP, biohydrogen
Measured gas volume Anaerobic gases (eg. biogas, biomethane, biohydrogen production)
Number of measurement channels 9
Reactor volume 2.0 L
Gas composition estimation No
Operation modes Batch
Carbon dioxide removal Ex-situ
Measurement resolution 2 mL or 9 mL
Software Aurora included
AMPTS III DUO
Application areas Biogas, biomethane, BMP, SMA, RGP, biohydrogen
Measured gas volume Anaerobic gases (eg. biogas, biomethane, biohydrogen production)
Number of measurement channels 18
Reactor volume 0.5 L or 1.0 L
Gas composition estimation Yes (two detection units included)
Operation modes Batch
Carbon dioxide removal Ex-situ
Measurement resolution 2 mL or 9 mL
Software Aurora software
AMPTS III Light DUO
Application areas Biogas, biomethane, BMP, SMA, RGP, biohydrogen
Measured gas volume Anaerobic gases (eg. biogas, biomethane, biohydrogen production)
Number of measurement channels 9
Reactor volume 2.0 L
Gas composition estimation Yes
Operation modes Batch
Carbon dioxide removal Ex-situ
Measurement resolution 2 mL or 9 mL
Software Aurora software

Choose your incubation setup

AMPTS® III can be used with either a thermostatic water bath or BPC® Air, depending on your laboratory setup, test duration and preferred incubation method.

BPC® Air

BPC® Air is an air based incubation unit for BPC respirometer systems, including AMPTS® III. It provides both cooling and heating from 10 to 60 °C and can be configured for aerobic and anaerobic workflows.

By using air as the heating and cooling medium, BPC® Air removes the need for water refills during operation. Its floor standing design with wheels also makes it easier to position and move in the laboratory.


Thermostatic water bath

The thermostatic water bath is the traditional incubation setup for AMPTS® III workflows. It provides water based temperature control and remains a suitable option for laboratories that already work with this type of configuration or prefer water based incubation.


The AMPTS systems are more than just data generators; they are reliable tools that have significantly contributed to our research. The user-friendly operation and high level of automation make them stand out among the methods we use for BMP determination in our lab, which include mainly manual methods. Their reliability is unmatched, making them the most popular choice for our research.

PROF. KONRAD KOCH
TECHNICAL UNIVERSITY OF MUNICH, GERMANY

Want to know more?

Need help choosing between AMPTS® III models?

Tell us about your sample throughput, reactor volume and test type. We can help you identify the right configuration.

Technical Specifications

Incubation unit

The sample incubation unit keeps reactors at a controlled temperature during BMP testing, with mechanical stirring for consistent sample mixing. It supports 9 or 18 reactors and is available with different reactor volumes to match the needs of each experiment.

Maximum number of reactors per system 

18 or 9


Reactor material

Glass


Standard reactor volume

1000 mL (with option for 500 mL) and 2000 mL


Type

Thermostatic water bath


Dimensions

56 x 68 x 32 cm


Temperature control 

Up to 60 °C (203 °F) with a precision of 0.2 °C


Mixing in the reactor

mechanical agitation with brushless DC motors (adjustable interval, speed and rotation directions), max. speed 200 rpm


Power supply

Carbon dioxide absorption unit

The carbon dioxide absorption unit removes CO₂ from the gas stream before measurement, allowing AMPTS® III to measure methane production directly during BMP testing. Each trap bottle is prepared with absorption liquid* and connects between the reactor and detection unit.

*Absorption liquid is not included with the instrument

Carbon dioxide trap bottles

18 or 9


Volume of carbon dioxide trap bottles

250  mL


Dimensions

54 x 27 x 12 cm (including bottles)


Recommended absorption liquid*

3 M NaOH with pH indicator*, 200 mL per bottle (not included) Absorption efficiency: >98%

Detection unit

The detection unit records gas production from up to 18 channels using liquid displacement and buoyancy. Built-in sensors and onboard electronics support stable, automated measurement, with data transferred to Aurora™ for monitoring, analysis and export.

Working principle

Liquid displacement and buoyancy 


Number of flow cell units

18 or 9


Dimension of unit

55 x 19 x 17 cm


Housing

Aluminium and plastic


Built-in sensors

Temperature, Pressure, Hall, Accelerometer 


Connections 

Up to 60 °C (203 °F) with a precision of 0.2 °C


Display

OLED 2.8” 256 x 64 white 


Power supply

12 V DC / 1.0 A with 100-240 VAC 


Measurement medium

Deionised or distilled water


Operation temperature

0 – 50o C


Operation pressure

-50 – 50 mbar


Gas connector diameter

ID: 2.4 – 2.6 mm; OD: 4.2-4.7 mm 


Recommended tubing size

ID: 4 mm;  OD: 6 mm 


Measuring resolution

9 mL (standard) with 2 mL as option 


Detection capacity

10 million data points


Measuring range

1 to 6000 mL/h for 9 ml flow cell  and 0.2 to 1500 mL/h


Repeatability

CV ≤ 1% for 9 ml flow cell and CV ≤ 3% for 2 ml flow cell 


Gases

Non aggressive gases (e.g. CH4 , CO2 , H2 , N2 ,…)

Downloads

Download product brochures and comparison documents.

Looking for manuals or other technical documentation?
You can find them in BPC Academy, our customer resource and training centre.

Related spare parts

Common questions about
AMPTS® III

AMPTS® III is used for automated anaerobic batch fermentation testing. Typical applications include BMP testing, SMA assays, residual gas potential analysis, inhibition studies, biogas potential and anaerobic biodegradability testing.


AMPTS® III has 18 reactor channels, while AMPTS® III Light has 9 reactor channels. Both systems are designed for the same anaerobic batch fermentation applications, but the Light version is suited for lower sample throughput.


Yes. AMPTS® III can measure accumulated biomethane when the CO₂ absorption unit is used. Without the CO₂ absorption unit, the system can be used to measure total biogas.


No. AMPTS® III has an embedded server and local data storage. Aurora™ software is accessed through a web browser, so no software installation on an external computer is required.


AMPTS® III is used for non-aggressive gases such as methane, carbon dioxide, hydrogen and nitrogen, depending on the experimental setup.

Yes. AMPTS® III can be used for residual gas potential analysis, including tests where low gas production is measured over longer incubation periods.

Yes. Multiple AMPTS® systems can utilised to increase analytical capacity, however each system is operated as a standalone unit with its own access, software and data storage.


Scientific References

Talk to an expert about AMPTS® III

Share your application, expected sample throughput and the type of gas measurement you need. Our product experts can help you choose the right AMPTS® III configuration and suitable accessories for your laboratory.

"*" indicates required fields